KwiKool BIOair MAX™ KBX1800 with Advanced Bi-polar Ionization Technology (BPI), UV-C Lighting and HEPA Filtration

$4,695.00

Contact Our Expert Team
 

Hermetically-Sealed Air System

Rapid Air Changes Per Hour for Larger Spaces

(See our downloadable chart below for air exchanges per hour)

 

YOUR CHOICE of One or More Air Purification Technologies in One Portable Unit

 

PORTABLE AIR CLEANING AND PURIFICATION

IDEAL FOR SCHOOLS, OFFICES, HEALTHCARE SETTINGS
AND OTHER SPACES WHERE PEOPLE GATHER
AND AIRBORNE PATHOGENS LIKE COVID ARE A CONCERN

The BIOair MAX™ KBX1800 combines the best features of the BIOairfamily of products with HEPA air filtration plus air purification with UV-C lighting and  advanced Bi-polar Ionization Technology (BPI) – all working in tandem to help kill airborne pathogens in larger spaces.

As an optional special order, this unit can also be customized to create negative air.

BIOair products provide them all in an hermetically-sealed air system. Other models (KBP1800 Plus and KBA1800) are available with fewer features at a lower cost.

See the chart below for other models in the BIOair family product line.

 

BIOair MAX™ KBX1800 Features

  • Advanced Bi-polar Ionization Technology (BPI) to help kill airborne pathogens, including viruses
  • Internal UV-C lights to help kill airborne pathogens
  • HEPA Filtration with pre-filter—99.97% efficiency for particulates .3 microns or more in diameter 
  • Delivers 27 CPH in a 4000 cubic foot space (20’x20’x10’)
  • Stainless steel cabinet
  • Small footprint: 23″W x 26.25″D x 46″H
  • Operates on standard 115V power
  • ETL- certified
  • Optional Carbon filter
  • UV-C timer alarm
  • HEPA filter alarm
  • Touchscreen controls
  • Optional carbon filter
  • dB = 69

 

BIOair MAX™ KBX1800 Specifications

  • Fan Type (Centrifugal) – 3-Speed 1550/1675/1800 DIRECT DRIVE
  • UVC Light Wave length – UVC 17 Watts/Max 85 Watts/Light
  • Total Ion Output – > 300 Million ions/cc
  • Power Supply (Volts) – 115V
  • Current Consumption (Amps) – 9.95
  • Recommended Breaker Size – 15
  • Minimum Circuit Ampacity (Amps) – 12.67
  • Min/Max Voltage – 105-125 Amps
  • Plug Configuration – NEMA 5 -15
  • Weight (lbs.) 135
  • Shipping Weight (lbs.) – 170
  • Fan Motor Overload – Automatic Internal
  • Automatic Restart – YES
Compare our full line of KwiKool BIOair™ Units including our newest systems with advanced Bi-polar Ionization Technology (BPI).

Please see the chart below for information on the BIOair™ line of products.

Specification Sheet CPH Chart KBX Series Information

Adobe Reader

Categories: , SKU: PAG-KBX1800-102820 Tags:
Brands:

Description

CUSTOMIZE YOUR BIOair

TO FIT YOUR NEEDS, YOUR SPACE , YOUR BUDGET

BIOair™ FAMILY OF AIR CLEANERS AND PURIFIERS
HEPA
(99.97%)
UV-C
NEGATIVE AIR
ADVANCED BIPOLAR IONIZATION
2000 cubic feet
CPH
4000 cubic feet
 CPH
6000 cubic feet
CPH
CADR
KBA600 YES N/A YES  N/A 18 9 6 599.82
KBP600 PLUS YES YES YES  N/A 18 9 6 599.82
KBX 600 YES YES YES YES 18 9 6 599.82
KBA1000 YES N/A YES  N/A 30 15 10 999.7
KBP1000 PLUS YES YES YES  N/A 30 15 10 999.7
KBX1000 YES YES YES YES 30 15 10 999.7
KBA1800 YES  N/A  YES  N/A 54 27 18 1799.46
KBP1800 PLUS YES YES  YES  N/A 54 27 18 1799.46
KBX1800 MAX YES YES YES YES 54 27 18 1799.46

ASK US ABOUT THE CPH YOU CAN EXPECT IN YOUR SPACE

CONTACT US for DETAILS

Typical Air Changes Per Hour Table

Experts in interior air flow management recommend the following air changes per hour*

RESIDENTIAL

Basements 3-4
Bedrooms 5-6
Bathrooms 6-7
Family Living Rooms 6-8
Kitchens 7-8
Laundry 8-9

OFFICES

Business Offices 6-8
Lunch Break Rooms 7-8
Conference Rooms 8-12
Medical Procedure Offices 9-10
Copy Rooms 10-12
Main Computer Rooms 10-14
Smoking Area 13-15

RESTAURANTS

Dining Area 8-10
Food Staging 10-12
Kitchens 14-18
Bars 15-20

PUBLIC BUILDINGS

Hallways 6-8
Retail Stores 6-10
Foyers 8-10
Churches 8-12
Restrooms 10-12
Auditoriums 12-14
Smoking Rooms 15-20
*Rob Falke, Contracting Business 24 March 2016

DOWNLOAD Charts

 

CERTIFICATIONS

3 certifications logos ETL, UL, UL Validated

             UL2998                   UL867                Intertek ETL

OZONE EMISSION CERTIFICATION

The advanced bi-polar ion generator used in BIOairunits KBX 600, KBX 1000 and KBX 1800 MAX has been tested for ozone emissions by Intertek, a leading Total Quality Assurance provider to industries worldwide.  The ozone generation was 0.003 ppm, significantly BELOW the allowable ozone limit of 0.050 ppm .  This complies with requirements of Underwriters Laboratories Standard  UL 867, Section 40 Fifth Edition, August 4, 2011 revision: august 7, 2018.

 

 

Disclaimer

Advanced Bi-polar Ionization Technology (BPI) is used in a wide range of applications across diverse environmental conditions. Since locations will vary, users should evaluate their individual applications and environmental conditions when making an assessment regarding this technology’s potential benefits. The use of this technology is not intended to take the place of reasonable precautions to prevent the transmission of airborne pathogens. It is important to comply with all applicable public health laws and guidelines issued by federal, state, and local governments and health authorities as well as official guidance published by the Centers for Disease Control and Prevention (CDC), including but not limited to proper use of hard surface disinfection with products listed on the EPA’s “N” List, social distancing, hand hygiene, cough etiquette, and the use of face masks.